- Brands
- Recorders
- Video Management Software & Cloud
- Lenses
- Audio & Paging
- Networking
- Access, Intercoms & Door Phones
- Mounting & Accessories
- Tools & Test Equipment
- Connectors
- Cables
- Illumination
- Intrusion & Alarm
- Smart Home & Automation
- Power & Protection
- Storage
- Racks and Accessories
- POS
- Video Servers
- Video Encoders and Decoders
- Monitors
- Others
- Clearance
- VMS
- Brands
- Recorders
- Video Management Software & Cloud
- Lenses
- Audio & Paging
- Networking
- Access, Intercoms & Door Phones
- Mounting & Accessories
- Tools & Test Equipment
- Connectors
- Cables
- Illumination
- Intrusion & Alarm
- Smart Home & Automation
- Power & Protection
- Storage
- Racks and Accessories
- POS
- Video Servers
- Video Encoders and Decoders
- Monitors
- Others
- Clearance
- VMS
- Home
- Network Switches
- Cyber Power - MBP63A2 - Maintenance Bypass PDU, 2U rack/tower/wall, 200-240V, 1 NEMA L6-20R, 1 NEMA L6-30R, Terminal Block, 3 year warranty Cyber Power - MBP63A2 - Maintenance Bypass PDU, 2U rack/tower/wall, 200-240V, 1 NEMA L6-20R, 1 NEMA L6-30R, Terminal Block, 3 year warranty
Cyber Power - MBP63A2 - Maintenance Bypass PDU, 2U rack/tower/wall, 200-240V, 1 NEMA L6-20R, 1 NEMA L6-30R, Terminal Block, 3 year warranty
- Description
- Specifications
- Downloads
- Reviews
Maintenance Bypass PDU, 2U rack/tower/wall, 200-240V, 1 NEMA L6-20R, 1 NEMA L6-30R, Terminal Block, 3 year warranty
Designed for datacenters and other electrically demanding applications, the CyberPower MBP63A2 Maintenance Bypass Power Distribution Unit (MBP PDU), allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The MBP63A2 provides 208V nominal output to (1) NEMA L6-20R, (1) NEMA L6-30R and (1) Hardwire Terminal Block receptacle.
Depending on UPS model, either a 3.3-foot AC cord or hardwire terminal block connects to the output power of the UPS. The UPS draws input power from the MBP63A2 separate from the outlets or terminal block for connected devices. When the switch on the front of the MBP63A2 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active.
Rugged, industrial-grade metal housing protects the MBP63A2. With a 2U form factor, this PDU can be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration. The MBP63A2 is UL and RoHS compliant. A three-year limited warranty covers the PDU.
Features:
- Power Distribution: Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
- Maintenance Bypass: Qualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.
- Manual Bypass Switch: When the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.
- MBP Detection Cable: Communicates directly between the UPS and Maintenance Bypass PDU to safely coordinate the bypass switch operation. When the PDU bypass switch operation is initiated by removing the cover, the MBP Detection Cable sends a signal to the UPS to internally transfer to bypass mode to prevent UPS damage.
- Network-Grade Plugs and Outlets: Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
- 2U Form Factor & Mounting Hardware: The 2U form factor is made to be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration.
- Durable Metal Housing: Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.
- Three-Year Limited Warranty: Covers defects in materials and workmanship in the product under normal use and conditions. See warranty for details.
| Input | |
|---|---|
| Cord Length | 3.3 ft (1.0 m) |
| Inlet To UPS Input | (1) Terminal Block |
| Inlet To UPS Output | (1) Terminal Block |
| Inlet To Utility Power | (1) Terminal Block |
| Input Plug Type | Hardwire |
| Input Voltage Range | 200 VAC – 240 VAC |
| Maximum Input Current | 63A |
| Output | |
| Nominal Output Voltage | 208 VAC |
| Number of Outlets | 3 |
| Outlet Type | 1 – NEMA L6-20R 1 – NEMA L6-30R 1 – Hardwire Terminal Block |
| Outlets – Total | 3 |
| Overload Protection | None |
| USB Charge Port | No |
| Management & Communications | |
| Management Cable | MBP Detection Cable 3.3 ft. |
| Physical | |
| Form Factor | Rack / Tower |
| Form Factors Supported | 2U Rackmount |
| Material of Construction | Metal |
| Rack Height | 2U |
| Dimensions | |
| Physical Dimensions – (WxHxD) (cm) | 43.18 x 8.64 x 12.45 (cm) |
| Physical Dimensions – (WxHxD) (in) | 17 x 3.4 x 4.9 (in) |
| Physical Dimensions – (WxHxD) (mm) | 432 x 86 x 124 (mm) |
| Physical Weight (kg) | 3.99 |
| Physical Weight (lb) | 8.8 |
| Dimensions – Shipping | |
| Shipping – Weight (kg) | 7.48 |
| Shipping – Weight (lb) | 16.5 |
| Shipping Dimensions – (WxHxD) (cm) | 52.07 x 18.03 x 45.21 (cm) |
| Shipping Dimensions – (WxHxD) (in) | 20.5 x 7.1 x 17.8 (in) |
| Shipping Dimensions – (WxHxD) (mm) | 520.7 x 180.34 x 452.12 (mm) |
| Environmental | |
| Operating Elevation | 0 – 10000 ft (0 – 3048 m) |
| Operating Relative Humidity | 0 – 90 % (non-condensing) |
| Operating Temperature | 32 – 104 °F (0 – 40 °C) |
| Storage Elevation | 0 – 50000 ft (0 – 15239 m) |
| Storage Temperature | -4 – 113 °F (-20 – 45 °C) |
| Compatibility | |
| UPS Models | OL5KRTHD, OL6KRTHD, OL5KRTHDL, OL6KRTHDL, OL8KRTHD, OL10KRTHD, OL6KRT, OL8KRT, OL10KRT |
| Certifications | |
| Environmental | RoHS Compliant |
| Safety | UL 1778 |
| Warranty | |
| Extended Warranty Option | WEXT5YR-ACC2B |
| Product Warranty | 3 Year Limited Warranty |